Library / Guideline for Management of GHG and Fugitive Emissions from Midstream and Downstream Petroleum Operations
Guideline for Management of GHG and Fugitive Emissions from Midstream and Downstream Petroleum Operations
Page 25 of 49
?
NIGERIAN MIDSTREAM AND
¢ DOWNSTREAM PETROLEUM
:
;
REGULATORY AUTHORITY (NMDPRA)
Applicable to all Midstream and Downstream
Petroleum Operations
GUIDELINES FOR MANAGEMENT OF GREEN HOUSE GASES {GHG}
AND FUGITIVE EMISSIONS FROM MIDSTREAM AND DOWNSTREAM
PETROLEUM OPERATIONS IN NIGERIA
3.7
Centrifugal Compressor Seals
3.7.1
Control Requirements
A licensee or permit-holder is required to utilize centrifugal compressors with dry
seals. Where compressors with wet seals are in place, a licensee or permit-holder
is required to:
a. Route
oil degassing
unit emissions
either
to
a Vapor Recovery System
(including
routing
the
emissions
to
the
inlet
of
the
compressor}
or
a
combustion device.
lb. Ensure the use of compressors with dry seals or retrofit existing compressors
using dry seals within 180 days.
3.7.2
Monitoring
As
part
of
instrumental
LDAR,
a
licensee
or
permit-holder
shall
inspect
compressors, wet seals, isolation valves, Vapor Recovery System
or control
devices, every 90 days.
3.7.3
Reporting
A licensee or permit-holder shall submit an annual report not later than 90 days
of the preceding year, stating level of compliance and record of any deviations,
along with
certification
of the
truth and accuracy
of report signed
by
a
competent person.
3.8
Reciprocating Compressor Rod-Packing.
3.8.1
Requirements for Control
Emissions from compressor vents shall be routed using one of the following
control options:
24
GuidelinesPDF202525