Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020 Revision Date: 1st August 2020 This is a property of the Department of Petroleum Resources. All rights reserved 10 4.4 Operating Conditions The Producers shall report the operating temperature and pressure of produced natural gas and Flare Gas. 4.5 Computed Associated Gas and Flare Gas data The Producer is required to calculate and report per Oil Field and Flare Site: a. Gas-to-Oil Ratio (GOR) in scf of Associated Gas produced per bbl of Crude Oil and/or Condensate produced b. Associated Gas Utilisation Factor (AGUF) c. Routine and Non-Routine Flaring quantities 4.6 Metering The following provisions shall apply to the Producer and, where applicable, to the Permit Holder as provided in Section 4.6 (d) (2) and to Processing Facilities as provided in Section 4.6 (d) (3): a. Gas Measurements to obtain accurate and accredited data 1. The parameters/requirements listed below are determining factors in selection of the type of meter to be installed for the purpose of gas measurements and production data management: i. Composition of the gas ii. Required accuracy / margin of error iii. Measurement intervals / duration / range iv. Calibration frequency and procedures v. Data storage and retrieval process