Afrindustria/ Gas Gap Monitor

Library / Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Page 12 of 42

Open the PDF at page 12

 
 
 
 
Applicable to all Oil & Gas Operators  
GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & 
REPORTING OBLIGATIONS 
Code: DPR Guide 0005 - 2020 
 
Revision Date: 1st August 2020 
 
 
This is a property of the Department of Petroleum Resources. All rights reserved  
12 
iii. Category of meters: Orifice meters, Coriolis meters, ultrasonic meters or any 
other meters approved by the Department of Petroleum Resources 
iv. Standards that govern the Flare Payment Fiscal Meter and Flare Gas Sales 
Fiscal Meter are the same as those described in Section 4.6(b) (1) (iv): 
a) 
API, ISO as above and AGA No. 7 for Turbine meters; and 
b) 
Any other reputable industry standards, acceptable to the 
Department of Petroleum Resources 
3. 
Allocation Meters and meters used by Processing Facilities: Requirements for 
selection of Allocation Meters and meters used by Processing Facilities shall 
include the following: 
i. Accuracy: +/- 5.0% 
ii. Operating range (pressure, flow and composition) shall be set by the 
anticipated range of measurements  
iii. Type of meters: Orifice meters, Coriolis meters, turbine meters, ultrasonic 
meters or any other meters approved by the Department of Petroleum 
Resources 
iv. Standards: API, ISO as stated above in Section 4.6 (b) (1) (iv) and for turbine 
meters AGA 7 & API MPMS 20.1 and any other reputable industry 
standards, approved by the Department of Petroleum Resources 
c. 
Other applicable metering standards 
Other applicable standards relevant to the metering system designs and operations shall 
include the following: