Afrindustria/ Gas Gap Monitor

Library / Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Page 14 of 42

Open the PDF at page 14

 
 
 
 
Applicable to all Oil & Gas Operators  
GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & 
REPORTING OBLIGATIONS 
Code: DPR Guide 0005 - 2020 
 
Revision Date: 1st August 2020 
 
 
This is a property of the Department of Petroleum Resources. All rights reserved  
14 
e) Quantity of gas used by any other equipment using gas as fuel 
iii. 
Liquids 
Production Meters shall be installed to measure the recovered liquids 
such as condensate and LPGs, and to determine the equivalent quantity 
of Associated Gas   
iv. 
Flare Gas 
A Fiscal Meter as specified in Section 4.6 (b) (2) above shall be deployed 
for the following Associated Gas and Flare Gas quantities that generate a 
payment: 
a) Flare Gas delivered to Producer’s Approved Flare Out Project 
b) Flare Gas to the Flare Stack or Incinerator 
2. 
The Permit Holder shall deploy Fiscal Meters as specified in Section 4.6 (b) (2) as 
follows: 
i. Delivery Point of Flare Gas delivered to Third Party Flare Commercialisation 
Project 
ii. Header where Project gas is directed to the Flare Stack or Incinerator 
3. Other Processing Facilities shall deploy meters as specified in Section 4.6 (b) (3) to 
meter natural gas flow to the Flare Stack, Incinerator or vent stack.   
4.7 
Producers’ Unaccounted Flare Gas 
The Unaccounted Flare Gas quantities are calculated as follows:  
Unaccounted Flare Gas quantities = (A*B) - C - D - E - F - G - H, 
where: