Library / Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020
Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020
Page 14 of 42
Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020 Revision Date: 1st August 2020 This is a property of the Department of Petroleum Resources. All rights reserved 14 e) Quantity of gas used by any other equipment using gas as fuel iii. Liquids Production Meters shall be installed to measure the recovered liquids such as condensate and LPGs, and to determine the equivalent quantity of Associated Gas iv. Flare Gas A Fiscal Meter as specified in Section 4.6 (b) (2) above shall be deployed for the following Associated Gas and Flare Gas quantities that generate a payment: a) Flare Gas delivered to Producer’s Approved Flare Out Project b) Flare Gas to the Flare Stack or Incinerator 2. The Permit Holder shall deploy Fiscal Meters as specified in Section 4.6 (b) (2) as follows: i. Delivery Point of Flare Gas delivered to Third Party Flare Commercialisation Project ii. Header where Project gas is directed to the Flare Stack or Incinerator 3. Other Processing Facilities shall deploy meters as specified in Section 4.6 (b) (3) to meter natural gas flow to the Flare Stack, Incinerator or vent stack. 4.7 Producers’ Unaccounted Flare Gas The Unaccounted Flare Gas quantities are calculated as follows: Unaccounted Flare Gas quantities = (A*B) - C - D - E - F - G - H, where:
CodesPDF20202020-0814