Afrindustria/ Gas Gap Monitor

Library / Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Page 17 of 42

Open the PDF at page 17

 
 
 
 
Applicable to all Oil & Gas Operators  
GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & 
REPORTING OBLIGATIONS 
Code: DPR Guide 0005 - 2020 
 
Revision Date: 1st August 2020 
 
 
This is a property of the Department of Petroleum Resources. All rights reserved  
17 
c. 
Accounted liquids extracted from Associated Gas 
In the event that the Producer does not measure the Associated Gas quantities going in and 
out of the Associated Gas processing unit (extracting liquids from Associated Gas) the 
equivalent Associated Gas quantities may be computed from metered liquid production. 
d. 
Accounted Flare Gas 
The Accounted Flare Gas quantities are calculated as follows:  
Accounted Flare Gas quantities = (A* B) - C- D - E - F - G, 
where: 
A = Associated Gas Production quantities (metered or accounted)  
B = 1 - Shrinkage Factor 
C = Own Consumption quantities (metered or accounted) 
D = Gas for Existing Offtake Commitments (metered)  
E = Liquids extracted from Associated Gas (if metered or accounted for)  
F = Flare Gas delivered to Third Party Flare Commercialisation Projects 
(metered)  
G = Flare Gas delivered for Producers’ Approved Flare Out Projects (metered).   
The Producer shall indicate which data are metered and which are accounted for in the 
reporting template provided by the Department of Petroleum Resources. 
4.10 
Unaccounted Project Flare Gas 
Unaccounted Project Flare Gas refers to Flare Gas quantities that the Permit Holder cannot 
account for with respect to the Flare Gas quantities delivered to the Project, Project Flare Gas