Afrindustria/ Gas Gap Monitor

Library / Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Page 35 of 42

Open the PDF at page 35

 
 
 
 
Applicable to all Oil & Gas Operators  
GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & 
REPORTING OBLIGATIONS 
Code: DPR Guide 0005 - 2020 
 
Revision Date: 1st August 2020 
 
 
This is a property of the Department of Petroleum Resources. All rights reserved  
35 
Flare Gas Measurement, Data Management and Reporting 
Obligations during which the Producers and Processing Facility 
operators shall install the metering systems as laid out in the 
Guidelines for Flare Gas Measurement Data Management and 
Reporting Obligations 
Unaccounted Flare Gas   Flare Gas quantities that Producers cannot account for, calculated 
as (A*B) - C - D - E - F - G - H, where: 
A= Associated Gas Production quantities  
B= 1 - Shrinkage Factor 
C= Own Consumption quantities 
D= gas quantities delivered under Existing Offtake Commitments  
E= Liquids extracted from Associated Gas (if metered or 
accounted for)  
F= Flare Gas delivered to Third Party Flare Commercialisation 
Project  
G= Flare Gas delivered for Producers Approved Flare Out Project  
H= measured or accounted Flare Gas quantities going to the Flare 
Stack 
Unaccounted Project 
Flare Gas 
Flare Gas quantities that the Permit Holder cannot account for 
with respect to the Flare Gas quantities and composition 
delivered to the Project, own consumption and the Flare Gas- to- 
Market Product quantities 
Vented Gas 
Gas that is released into the environment without being 
combusted 
Vented Gas Quantity 
The quantity of Flare Gas vented either by a Producer, a Permit 
Holder or a Processing Facility operator 
Vented Gas Report 
Report prepared by the Producer as defined in Schedule B 1.2.4 of 
the Guidelines for Flare Gas Measurement, Data Management and 
Reporting Obligations