9. SCHEDULE A 
Measurement Points for Producers and Permit Holders 
 
 
10. Table 1: METER INSTALLATION POINTS 
ENTITY 
WHAT 
WHERE 
Producers 
Associated Gas Production per Flare Site  
 
In the flowlines immediately downstream 
of where Crude Oil, water and Associated 
Gas are separated (A1 and A2 above) 
Producers 
Producers Associated Gas volume for Own 
Consumption 
In the flowlines delivering gas to the 
consumption points (B above) 
Producers 
Sales to Existing Offtake Commitments 
(including Producers’ Associated Gas 
Utilisation Projects for Commercialisation) 
At the corresponding delivery point (C 
above) 
Producers 
Flare Gas sales to Producer’s Approved Flare 
Out Project 
 
At the corresponding delivery point (F 
above) 
Producers 
Flare Gas volume going to Flare Stack per 
Flare Site and per Field 
In the Flare Gas Header downstream of all 
possible Flare Gas Header junctions.  No 
Flare Gas is allowed to by-pass the Flare 
Gas meter while being directed to the 
Flare Stack (G above). In the event that 
the Producer has a knock out drum  
installed in the Flare Gas Header, the Flare 
Gas meter should be installed downstream