Afrindustria/ Gas Gap Monitor

Library / Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Applicable to all Oil & Gas Operators GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & REPORTING OBLIGATIONS Code: DPR Guide 0005 - 2020

Page 39 of 42

Open the PDF at page 39

 
 
 
 
Applicable to all Oil & Gas Operators  
GUIDELINES FOR FLARE GAS MEASUREMENT, DATA MANAGEMENT & 
REPORTING OBLIGATIONS 
Code: DPR Guide 0005 - 2020 
 
Revision Date: 1st August 2020 
 
 
This is a property of the Department of Petroleum Resources. All rights reserved  
39 
f. 
Composition of produced Associated Gas and Flare 
Gas 
g. Own Consumption quantity in Mscf/d 
i. 
Power (electrical and mechanical drive) 
ii. 
Heat 
iii. 
Re-injection 
iv. 
Gas-lift (make-up gas) 
v. 
Any other (describe) 
h. AG Existing Offtake Commitment quantity in 
Mscf/d: 
i. 
Export 
ii. 
Domestic market 
i. 
AG Existing Offtake Commitment delivery in Mscf/d 
i. 
Export 
ii. 
Domestic market 
j. 
Flare Gas to Producer’s Approved Flare Out Project 
quantity in Mscf/d 
k. Flare Gas to Third Party Flare Commercialisation 
Project in Mscf/d 
l. 
Producer Flare Gas Flared quantity in Mscf/d 
i. 
Routine Flaring 
ii. 
Non-Routine Flaring 
m. Producer Vented Gas Quantity in Mscf/d 
n. Unaccounted Flare Gas quantity (in most cases AG 
that is vented) in Mscf/d 
o. Deliver or Pay Shortfall quantity in Mscf/d (Producer 
was not able to deliver) 
p. Contracted Guaranteed Flare Gas Buyer Shortfall 
quantity in Mscf/d (Permit Holder was not able to 
take) 
q. Force majeure events (start/end and duration) 
1.2.2 Producer Own 
(Energy) Consumption 
a. Electric energy consumption in kWh (per month) 
generated with own source(s) 
i. 
Type of fuel used 
ii. 
Fuel consumption  
b. Electric energy consumption in kWh (per month) 
purchased from the grid or any other third party 
c. 
Mechanical power use in HP (compression for re-
injection, gas lift, etc. and pumps for water re-
injection and oil shipping) 
d. Heat usage in BTU/hr (per month)  
e. Gasoline, diesel or any other fuel used for vehicles 
Monthly 
1.2.3 Gas Meter Inventory: 
a. Log of all meters: 
i. 
Where it is located 
ii. 
Type of meter 
iii. 
Calibration log 
Monthly 
1.2.4 Venting Points 
Log indicating where there is Vented Gas for reporting 
Monthly