9 
not be a Producer, as stipulated in Paragraph 8 (3) of the Flare Gas (Prevention of Waste and 
Pollution) Regulations, 2018; both referred to as Permit Holders: 
1. 
Flare Gas consumption  
2. 
Flare Gas volumes vented or flared in the Project (if applicable) 
c. 
Refineries and other Processing Facilities  
1. 
Flare Gas volumes vented or flared 
4.3 
Composition  
a. 
The Producer shall monthly report the composition of the following gas streams: 
1. 
Low pressure gas from tanks or surge vessels 
2. 
Flare Gas in the Flare Gas Header 
3. 
Flare Gas at the Delivery Point (if different from Flare Gas in the Flare Gas 
Header) 
b. 
The Producer shall provide the composition of the natural gas using online 
Chromatograph, regular sampling and laboratory analysis, or any other methods approved by 
the Department of Petroleum Resources.  
c. 
The composition data provided by the Producer shall cover the range of C1 to a 
minimum of C7 and significant contaminants including, but not limited to, H2S, Hg, CO2 and 
N2.   
d. 
Where a Producer decides to use regular sampling and laboratory analysis, the gas 
shall be analysed in a laboratory and using a procedure, both of which have been approved 
by the Department of Petroleum Resources.  
e. 
Sampling should conform to industry acceptable standard, such as API MPMS 14.1 