B 786 (r) the result obtained during a survey carried out under paragraph (q) shall be recorded and made readily available on demand, and the Authority may appoint officials to witness any periodic survey carried out under paragraph (q) ; (s) all other applicable safety provisions for the design, construction, commissioning, operation and maintenance of pipelines shall be as stipulated in the current editions of the guidelines issued by the Authority ; and (t) inspections and maintenance operations shall be conducted according to original manufacturer specifications, company specific inspection procedures, or in accordance with the Risk Based Inspection (RBI) guidelines issued by the Authority and conform with best practices. 14. A manager shall ensure — (a) that there are adequate spares for critical safety equipment, and that such spares are made available and ready for use when required ; (b) development and continual update of a comprehensive Management of Change (MOC) Procedure for facilities and operations under its management ; (c) that deviations shall not be made from Standard Operating Procedures, equipment or process configuration and no change shall be made to the facility that may introduce risk, unless such deviation or change is risk assessed, subjected to MOC Procedures and approved in writing by the manager ; (d) that all deviations and changes shall be documented, systematically recorded and made available to the Authority on demand ; and (e) that Standard Operating Procedures (SOP) shall be developed for each major or safety critical equipment. 15. A manager shall ensure that— (a) proper hazardous area classification is carried out ; (b) there are restricted areas in which open light, fire and smoking are prohibited ; (c) adequate number of approved firefighting equipment are provided ; (d) adequate means designed to extinguish fires which may occur in midstream and downstream petroleum operations shall be provided and kept in readiness for immediate use ; (e) the firefighting equipment shall be inspected — (i) visually at least once a month in accordance with the manufacturer’s recommendations, and (ii) twice a year by a competent person, and always maintained in serviceable condition ; Spares, standards operating procedure and management of change Fire precaution and firefighting equipment
RegulationsPDF20232023-0616