Library / © 2019 Department of Petroleum Resources. All rights reserved Department of Petroleum Resources (DPR) PROCEDURE GUIDE
© 2019 Department of Petroleum Resources. All rights reserved Department of Petroleum Resources (DPR) PROCEDURE GUIDE
Page 49 of 114
48 | P a g e 1.4 Applicable Standards for Design, Installation, Operation and Maintenance of Meters The applicable standards for Design, Installation, Operation and Maintenance of Metering system shall be American Petroleum Institute Manual of Petroleum Measurement Standards (API MPMS) Chapters 4, 5, 6, 11, 12 and 13. 1.5 Positive Displacement Meters - PD Meters 1.5.1 Description This is basically a piece of equipment designed to measure a volume of liquid by separating it into measured quantities (displaced volume) and counting these quantities. Meters of this type can only measure in one direction; hence it is impossible to reverse flow through such meters. 1.5.2 Design and Selection 1.5.2.1 Principle The design shall be based on the Lease Automatic Custody Transfer System (LACT). The metering assembly shall therefore generally follow the guideline specified in the API Manual of Petroleum Measurement Standard Chapter 6 of LACT Systems. 1.5.2.2 Selection Criteria In selecting the meters, consideration shall be given to the viscosity and density of liquid, solid contents, expected flow rates and operational conditions. 1.5.3 Operation and Maintenance Flow rate through the bank shall be maintained at between 60% and 80% of the maximum name plate capacity of each meter. It shall be more acceptable to shut down some of the meters in the bank to maintain this optimum flow rate than to operate any of the meters below the 60% capacity. 1.6 Turbine Meters 1.6.1 Description This is a flow rate measuring device which works on the principle of a sensing rotor moving with a tangential velocity which is proportional to the volumetric flow rate. The corresponding volume of liquid passing through the meter is indicated on a pre-calibrated readout device. Meters of this type can measure reverse flows but for the purpose of this guide, no reversal of flow shall be allowed. 1.6.2 Design and Selection 1.6.2.1 These shall generally be carried out in accordance with the procedure outlined in API Manual of Petroleum Measurement Standards Chapter 5 Section 3 and other reference standards in section 1.4 above. 1.6.2.2 Adequate consideration shall be given to the required maximum and minimum flow rates, maximum operating pressure and temperature as well as solid particles in the liquid and the liquid properties. 1.6.2.3 Turbine meters shall not be considered for use at flow rates less than 1,500 barrels per hour because of the short span of linearity of such meters in this flow regime. However, meters shall be selected such that they operate always within the linear portion of their characteristic curves.
GuidelinesPDF49