1.4 Applicable Standards for Design, Installation, Operation and Maintenance of 
Meters 
The applicable standards for Design, Installation, Operation and Maintenance of Metering 
system shall be American Petroleum Institute Manual of Petroleum Measurement 
Standards (API MPMS) Chapters 4, 5, 6, 11, 12 and 13. 
1.5 Positive Displacement Meters - PD Meters      
1.5.1 Description 
This is basically a piece of equipment designed to measure a volume of liquid by separating 
it into measured quantities (displaced volume) and counting these quantities. Meters of this 
type can only measure in one direction; hence it is impossible to reverse flow through such 
meters. 
1.5.2   Design and Selection  
1.5.2.1 Principle 
The design shall be based on the Lease Automatic Custody Transfer System (LACT). The 
metering assembly shall therefore generally follow the guideline specified in the API Manual 
of Petroleum Measurement Standard Chapter 6 of LACT Systems. 
1.5.2.2 Selection Criteria 
In selecting the meters, consideration shall be given to the viscosity and density of liquid, 
solid contents, expected flow rates and operational conditions. 
1.5.3 Operation and Maintenance  
Flow rate through the bank shall be maintained at between 60% and 80% of the maximum 
name plate capacity of each meter. It shall be more acceptable to shut down some of the 
meters in the bank to maintain this optimum flow rate than to operate any of the meters 
below the 60% capacity. 
1.6   Turbine Meters 
1.6.1 Description 
This is a flow rate measuring device which works on the principle of a sensing rotor moving 
with a tangential velocity which is proportional to the volumetric flow rate. The 
corresponding volume of liquid passing through the meter is indicated on a pre-calibrated 
readout device.  Meters of this type can measure reverse flows but for the purpose of this 
guide, no reversal of flow shall be allowed. 
1.6.2   Design and Selection  
1.6.2.1 These shall generally be carried out in accordance with the procedure outlined in API 
Manual of Petroleum Measurement Standards Chapter 5 Section 3 and other 
reference standards in section 1.4 above.  
1.6.2.2 Adequate consideration shall be given to the required maximum and minimum flow 
rates, maximum operating pressure and temperature as well as solid particles in the 
liquid and the liquid properties. 
1.6.2.3 Turbine meters shall not be considered for use at flow rates less than 1,500 barrels 
per hour because of the short span of linearity of such meters in this flow regime. 
However, meters shall be selected such that they operate always within the linear 
portion of their characteristic curves.