64 | P a g e 2.1.6.5 The data obtained by comparing the reading on the thermometer with the corresponding ones on the standard instrument of the comparator shall be collated and plotted to generate a calibration curve for the instrument. 2.1.7 Presentation of Results 2.1.7.1 A report of the calibration of each thermometer shall be submitted to the Department of Petroleum Resources for appropriate review and approval. The report shall provide information on the certifying Agency for the primary standard thermometer and that for the secondary standard thermometer used during the exercise. The respective dates of the last calibration as well as the next calibration of the primary and secondary thermometers shall be furnished in the report. Also, a summary of the steps followed in calibrating the thermometer under test and any observations made during the exercise shall be contained in the report. 2.1.7.2 The report shall also include the calibration data and the curve established for the instrument after the exercise which must then be approved by the Department of Petroleum Resources before the thermometer is allowed for use. 2.1.7.3 Where the thermometer error exceeds the maximum allowable temperature measurement accuracy, error correction shall be made using the accuracy curve or table whenever the thermometer is used. 2.2 Calibration of Hydrometers and Densitometers 2.2.1 Accreditation Only companies or Institutions that possesses a current Petroleum Resources registration permit as an equipment calibrator shall be eligible to carry out hydrometer calibration with participation of representative(s) of The Department of Petroleum Resources. 2.2.2 Principle Hydrometers and Densitometers shall be calibrated by comparing the specific gravity, API gravity and density readings of the test liquids as given by the hydrometer/densitometer with those simultaneously observed on the secondary standard hydrometer/densitometer in a standard comparator device. 2.2.3 Frequency of Calibration All new hydrometers/densitometers shall be deemed calibrated before use and annually thereafter. Certificate of calibration issued by the manufacturer shall be acceptable as evidence of calibration of new hydrometers/densitometers. 2.2.4 Applicable Standard Calibration method shall be as outlined in latest ASTM E126 “Standard Test Method for Inspection, Calibration, and Verification of ASTM Hydrometers”, American Petroleum Institute Manual of Petroleum Measurement Standard (API MPMS) Chapter 9.1. For densitometers, American Petroleum Institute Manual of Petroleum Measurement Standard (API MPMS) Chapter 14.6 shall be followed. 2.2.5 Verification and Calibration The hydrometer/densitometer shall be inspected for linear dimensional accuracy as described in the reference standard after which its reading shall be standardized in accordance with the prescribed procedure in the standard for liquid with low surface tension. As much as practicable, samples of petroleum or petroleum product of similar characteristics with those whose gravity will be measured during the operational life of the
GuidelinesPDF65