65 | P a g e hydrometer/densitometer shall be used as the test liquid. The secondary standard hydrometer/densitometer to be used in the exercise shall have a valid certificate of its prior calibration against a primary standard hydrometer/densitometer which shall be issued by a recognized bureau of standard. 2.2.6 Presentation of Results A report of the calibration exercise shall be submitted to the Department of Petroleum Resources for approval before the hydrometer/densitometer can be used. This report shall be accompanied by a copy of the certificate of the calibration of the secondary standard hydrometer/densitometer that has been used as reference during the exercise. 2.3 Calibration of Pressure and Differential Pressure Measuring Devices 2.3.1 Accreditation Only companies or Institutions that possesses a current Petroleum Resources registration permit as an equipment calibrator shall be eligible to carry out Pressure and Differential Pressure Measuring instrument calibration with participation of representative(s) of The Department of Petroleum Resources. 2.3.2 Principle Pressure and Differential Pressure Measuring devices shall be calibrated by a pressure calibrator that is certified as intrinsically safe. The Pressure Calibrator shall have the ability to apply pressure to a pressure transmitter or pressure switch while simultaneously measuring the mA signal or switch contacts. 2.3.3 Frequency of Calibration All Pressure and Differential Pressure Measuring devices shall be calibrated and certified in the presence of DPR official before being put to use and thereafter annually. 2.3.4 Applicable Standard Calibration method shall be as outlined in latest applicable ASTM and American Petroleum Institute Manual of Petroleum Measurement Standard (API MPMS). 2.3.5 Verification and Calibration 2.3.5.1 All new Pressure and Differential Pressure Measuring devices shall be deemed calibrated before use and annually thereafter. Certificate of calibration issued by the manufacturer shall be acceptable as evidence of calibration. 2.3.5.2 If a Pressure and Differential Pressure Measuring device calibration error exceeds one-half of the scale division, error correction shall be applied whenever the instrument is used. 2.3.6 Presentation of Results A report of the calibration exercise shall be submitted to the Department of Petroleum Resources for approval before the Pressure and Differential Pressure Measuring device can be used. This report shall be accompanied by a copy of the certificate of the calibration of the secondary standard Pressure and Differential Pressure Measuring device that has been used as reference during the exercise.
GuidelinesPDF66