66 | P a g e 2.4 Calibration of Metal Tapes 2.4.1 Accreditation Only companies or Institutions that possesses a current Petroleum Resources registration permit as an equipment calibrator shall be eligible to carry out metal tape calibration with participation of representative(s) of The Department of Petroleum Resources. 2.4.2 Principle Calibration shall be based on comparison of the horizontal length of tape with that of a valid Master Tape calibrated in a recognized laboratory under the same tension at a reference temperature of 68oF (20oC). 2.4.3 Frequency of Calibration All new tapes shall be deemed calibrated and an attestation to this effect by the manufacturer shall be recognized as evidence of this calibration. Annually thereafter throughout the operational life of the tape. 2.4.4 Applicable Standard This shall be the API MPMS 2.2A or its latest ASTM equivalent standard. 2.4.5 Verification and Calibration 2.4.5.1 The tape shall be calibrated against the length of a secondary standard tape both under a tensile force of 1lb or 0.45kgf with both tapes being supported on a horizontal plane along their entire length. 2.4.5.2 The Master Tape shall be covered by a current certificate issued by a recognized bureau of standards as evidence of a recent calibration against a primary standard-length measure. 2.4.5.3 Both tapes (Master Tape and Working Tape) shall be inspected for kink before calibration. 2.4.6 Presentation of Results A report of calibration exercise shall be submitted to the Department of Petroleum Resources office for review and approval. However, the allowable tolerance limit of variation in total length of the steel tape shall be 0.005ft (0.0015m) for every 100ft (30.48m) of tape length. 2.5 Calibration of Vertical Cylindrical Tanks 2.5.1 Accreditation This shall be on job basis. Any corporate body proposed by an operator to carry out a tank calibration exercise shall formally apply to the Department of petroleum Resources for accreditation. Such application shall be considered in the light of the expertise and previous performance of the applying company, the proposed programme of calibration and chart computation, and other applicable conditions as specified by The Department of Petroleum Resources and shall be with participation of its representative(s). 2.5.2 Principle Calibration of vertical cylindrical tanks is a process of accurately measuring such parameters of a vertical storage tank like circumferences at specific locations, vertical height, plate thickness, weights and volume of internal and external fixtures and bottom plate with the
GuidelinesPDF67