76 | P a g e compartment shall be noted and recorded. A capacity chart of the tank car shall then be drawn up containing the calibrated capacities of each of the compartments. 2.8.7.5 Water weighing Procedures: A weighing device which has been certified for accuracy by a body or Agency recognized by the Department of Petroleum Resources shall be used for this exercise. 2.8.7.6 The net weight of water in each compartment of the tank car shall be obtained in turn and in accordance with the procedure outlined in the referenced standards. Based on this measurement, a calibrated capacity chart of each of the cargo compartments for the whole tank car shall be prepared. 2.8.8 Presentation of Results 2.8.8.1 A capacity chart shall be drawn up as described in the foregoing and it shall contain the ambient conditions during calibration, the references temperature of the stated capacities with each compartment properly identified. The chart shall also contain information on the certifying body for the primary volume measure or the weighing scale with a photocopy of the certificate of accuracy of the primary volume measurement available for inspection on request. 2.8.8.2 The chart shall show the capacity of each compartment according to incremental depth. The date of calibration, description of the tanker trailer and the name of the calibrating company shall be conspicuously displayed on the chart. In cases where calibration is by water weighing, Table Viii of API 2554 shall be used to establish the appropriate correction factor for the temperature effect on relative density. 2.9 Field-Standard Test Measure 2.9.1 Principle The Test Measure so calibrated shall be the basis for calibrating all Proving Systems. The Field-Standard Test Measure is a vessel fabricated to meet specific design criteria and calibrated by an accredited international agent of a recognized standardization body. The Field-Standard Test Measure shall be calibrated by a competent Laboratory that can provide traceability of its equipment to the US National Bureau of Standards or any other similar internationally recognized body. 2.9.2 Frequency of Calibration The Field –Standard Test Measure shall be calibrated every three years and shall be automatically rendered invalid by damage or dent to the body. 2.9.3 Calibration Procedure 2.9.3.1 Field –Standard Test Measure shall be calibrated by the accredited laboratory or agency in accordance with the provisions of API Manual of Petroleum Measurement Standard Chapter 4.7. 2.9.3.2 Calibration shall be made using water as calibration medium. Certified laboratory graduates may be used to measure, partial volumes of a test measure. Actual capacity of the test measure shall be used as Official capacity rather than the nominal capacity of the measure. Calibrations shall be maintained at +0.02 percent minimum.
GuidelinesPDF77