83 | P a g e 1.12.1 General Requirements 1.12.1.1 Gas quality The meter shall as a minimum requirement, operate with any of the normal range natural gas composition mixtures specified in AGA Report No.8, this includes relative density between 0.554 (pure methane) and 0.87. 1.12.1.2Temperature measurement Coriolis flow meters should operate over a temperature range of –40 to 200F (-40 to 93C). However, in extreme ambient environment, appropriate measures such as providing shade to reduce impact of direct sunlight to the meter should be considered. A thermowell should be installed upstream of the Coriolis sensor for temperature verification purposes 1.12.1.3 Pressure measurement The location of the pressure measurement should be made near the sensor. The pressure tap can be located either upstream of the sensor. 1.12.1.4 Vibration and Electrical noise Coriolis meter package should be installed far away from vibration sources like compressors, pumps, generators and electrical noise such as electromagnetic interference. 1.12.1.5 Piping Configuration The following components should be provided in the piping design: Isolation block valves, Pressure, blow down port and thermowell port. The pipe-works must be aligned and properly supported to minimize stress due to pressure, weight and temperature. 1.12.1.6 Mounting a. The sensor should be properly mounted, supported and aligned with the inlet and outlet flanges. A spool piece should be used in place of the meter to align pipe-work during the construction phase. b. The Coriolis transmitter shall be mounted to ensure easy access to communication equipment, displays and keypads. The Coriolis meter may have the transmitter mounted to the sensor or mounted remotely. 1.12.2 Orientation The sensor tubes should be positioned in such a way that the possibility of heavier components, such as condensate, settling in the vibrating portion of the sensor is minimized. 1.12.3 Minimum Performance Requirements The following minimum performance requirements shall be met by the meter, as supplied directly from the manufacturer, prior to making any calibration factor adjustments based on an independent third-party flow calibration of the meter. Repeatability: + 0.35% of reading for Qt < Qi < Qmax + 1.0% of reading for Qmin < Qi < Qt Where Qt is the transitional mass flow rate.
GuidelinesPDF84