Library / © 2019 Department of Petroleum Resources. All rights reserved Department of Petroleum Resources (DPR) PROCEDURE GUIDE
© 2019 Department of Petroleum Resources. All rights reserved Department of Petroleum Resources (DPR) PROCEDURE GUIDE
Page 87 of 114
86 | P a g e 3 Fluid measured (gas/liquid) 4 Meter type C METER TUBE 1 Flow conditioner (Yes/No) 2 Type of flow conditioner 3 How fastened? (welded/flanged/pinned) 4 Dimensions Length: Upstream diameter: Downstream diameter: First pipe connection: Second pipe connection: Upstream pressure tap: Downstream pressure tap: 5 Thermowell (Location, length, condition) 6 Pipe alignment (Yes/No) D PRESSURE TAPS 1 Orientation 2 Location of static pressure transducer (upstream/downstream) 3 No. of pressure taps 4 Pressure tap size 5 Condition of tap hole edge 6 Temperature probe type E METER PARAMETERS 1 Minimum flow rate 2 Maximum flow rate 3 Meter factor 1.15 MEASUREMENT OF GAS BY MULTIPATH ULTRASONIC METERS 1.15.1 Introduction Ultrasonic meters are inferential meters that derive the gas flow rate by measuring the transit times of high-frequency sound pulses. Transit times are measured for sound pulses transmitted and received between pairs of transducers positioned on or in the pipe. Pulses transmitted downstream with the gas flow are accelerated by the flow and pulses transmitted upstream against the gas flow along the identical acoustic path are decelerated. The difference in these transit times along the acoustic paths is related to the average gas flow velocity. 1.15.2 Design requirements: The design shall be done in accordance with AGA 9 and other relevant standards and should be done in such a way not to allow for settlement of liquids and sediments.