Page 89 of 114

Open the PDF at page 89

 
88 | P a g e 
 
 
Maximum Peak to Peak Error: ±1 .0% for qt ≤qi ≤qmax  
±1 .4% for qmin ≤qi ≤qt 
qt is the transition gas flow rate below which the expanded error limit is applicable 
qi is the actual gas flow rate passing through a UM under a specific set of test conditions 
qmin is the minimum gas flow rate through the UM that can be measured within the 
expanded error limit 
qmax is the maximum gas flow rate through the UM that can be measured within the 
expanded error limit. 
 
1.15.8 ULTRASONIC METER INSTALLATION REQUIREMENT 
 
1.15.8.1 Pressure taps 
At least one pressure tap shall be provided for measuring the static pressure in the meter. 
Each pressure tap hole should be between 1/8” and 3/8” nominal in diameter and cylindrical 
over a length at least 2.5 times the diameter of the tapping, measured from the inner wall 
of the meter body. The tap hole edges at the internal wall of the meter body should be free 
of burrs and wire edges and have minimum rounding. For a meter body with a wall thickness 
less than 5/16”, the hole should be 1/8” nominal in diameter. Pressure taps may be located 
at the top, left side and/or right side of the meter body. 
1.15.8.2 Piping installation 
Both the upstream and downstream piping configuration (with or without flow 
conditioners) shall be installed in such a way that the additional flow rate measurement 
error shall not be more than ±0.3% due to the installation configuration. 
1.15.8.3 Protrusions 
No part of the upstream gasket or flange face edge shall protrude into the flow stream more 
than 1% of the internal diameter to minimize flow disturbances especially at the upstream 
flange. However, thermowells are excluded from the protrusion limit.  
1.15.8.4 Meter body length and bores 
The UM bore and the adjacent upstream pipe along with the flanges should have the same 
inside diameter to within 1% of each other. 
1.15.8.5 Thermowells 
For unidirectional flow, the thermowell should be installed downstream of the meter. The 
thermowell should be located at least 6 inches from the flange weld or 2 ND whichever is 
larger, and no farther than 5 ND from the downstream USM flange face.  
The recommended insertion length for thermowells and sample probes is between 1 /3 ND 
to 1 /2 ND for line sizes NPS 2 to NPS 1 0 and 1 /5 ND to 1 /3 ND for line sizes NPS 12 and larger. 
Special thermowell design may be required for insertion lengths greater than 1 /3 ND. 
1.15.8 Environmental consideration  
Factors such as temperature, vibration and electrical noise shall be taken into consideration. 
Appropriate measures should be taken to mitigate extreme temperatures and excessive/ 
unnecessary vibration and electrical noise should be avoided