Library / © 2019 Department of Petroleum Resources. All rights reserved Department of Petroleum Resources (DPR) PROCEDURE GUIDE

© 2019 Department of Petroleum Resources. All rights reserved Department of Petroleum Resources (DPR) PROCEDURE GUIDE

Page 94 of 114

Open the PDF at page 94

 
93 | P a g e 
 
 
1.16.3 Determination of Density 
There are three ways of determining density: 
• Measuring its average value directly in the LNG carrier’s tank by means of 
densitometers. 
• Calculated based on an average composition of LNG in accordance with ISO 
6578 and the revised KLOSEK-McKINLEY method. 
• Using gas chromatograph. 
  
 
1.17 DETERMINATION OF TEMPERATURE AND PRESSURE 
 
1.17.1 PRESSURE 
At the time of gauging, the pressure in the cargo tanks shall be arithmetic average of the 
absolute pressure indicating device for each tank. One absolute pressure indicating device 
shall be fitted to the vapor space of each tanks and shall be accurate to ±5 mbars or a range 
800mbars to 1,400mbars absolute for purpose of calculation. 
 
1.17.2 Temperature 
At the times of gauging, the liquid temperature of the cargo shall be determined by 
calculating the arithmetic average of temperature indicated by the temperature resisting 
devices immersed in the LNG in all the tanks. Each tank has a minimum of 5 devices 
distributed over the entire height of the tanks and shall be accurate to ±0.2 ◦C above the 
range of -145◦C to -165◦C. (±1.5◦C outside the range). The vapour temperature shall be the 
arithmetic average of the temperatures indicated by the temperature devices which at the 
time of gauging are in the vapor space above the surface of the LNG. These temperatures 
shall be printed before and after the loading and unloading operations for calculating 
average temperature of LNG liquid and LNG vapor and shall be rounded to one decimal 
place in degree Celsius. 
 
1.17.3 Sampling determination of composition of LNG in accordance with ISO 8943. 
 
1.17.3.1 Sampling and vaporization of LNG shall be taken at both loading and unloading 
in the presence of DPR representatives. 
1.17.3.2 LNG samples shall be taken at different time intervals between the duration of 
the loading. Samples can be taken automatically or manually. 
1.17.3.4 The calibration of the chromatograph utilized during sampling shall be done in 
accordance with ISO 1411. 
1.17.3.5 Each set of samples obtained during loading or unloading shall be distributed as 
follows: 
i. 
First cylinder    - for use of seller at loading or buyer at unloading establishing 
the LNG composition for custody transfer by chromatographic analysis. 
ii. 
Second cylinder - for retention by seller at loading or buyer unloading for a 
period of twenty (20) days after the analysis of the first portion has been 
reported to the other party during which period any question as to the 
accuracy of any analysis shall be raised. In such case, the portion shall be used 
as buyer and seller may mutually agree; and  
iii. 
Third cylinder     - for the use by an independent surveyor.