Library / Applicable to all Oil & Gas Operators SAFETY CASE GUIDELINES FOR OIL AND GAS FACILITIES IN NIGERIA Code: DPR GUIDE 0036 – 2020 Revision Date: 2nd October 2020
Applicable to all Oil & Gas Operators SAFETY CASE GUIDELINES FOR OIL AND GAS FACILITIES IN NIGERIA Code: DPR GUIDE 0036 – 2020 Revision Date: 2nd October 2020
Page 8 of 24
8
Applicable to all Oil & Gas Operators
SAFETY CASE GUIDELINES FOR OIL AND GAS FACILITIES IN NIGERIA
Code: DPR GUIDE 0036 – 2020
Revision Date: 2nd October 2020
This is a property of the Department of Petroleum Resources. All rights reserved
Figure 1: Types of Safety Cases
Concept
Front End
Engineering
Design (FEED)
Detailed
Design/Fabrication
Operations
Decommissioning
*CSE
Design Safety
Case
Operational Safety Case
Decommissioning
Safety Case
1
4 SAFETY CASE CONTENT
(Applicable to Design, Operations and Decommissioning Safety Cases)
A facility’s Safety Case shall evidentially describe and/or broadly demonstrate, at a minimum, the
following:
i.
Introductory information
ii.
Signed Statement of Fitness
1 Concept Safety Evaluation (CSE) is the set of exercise(s)/assessment(s) carried out during the concept
selection stage of a project to comparatively assess and analyse the HSE risks associated with all the proposed
facility development options, with the aim of providing safety risks and justifications for the selected concept
option and then, demonstrate that the risk and safety considerations of the selected concept is ALARP.
CodesPDF20202020-108