Library / Extraordinary Federal Republic of Nigeria Official Gazette No. 33
Extraordinary Federal Republic of Nigeria Official Gazette No. 33
Page 6 of 17
6.—(1) The classes of dynamic measurement based on their purpose of deployment are specified in the First Schedule to these Regulations. (2) The uncertainty limit data analysis shall be dev eloped for petroleum measurement systems within 95% confidence level in accordance with recognised standards and the uncertainty limits shall be prescribed by the Authority in guidelines. (3) The points of deployment for dynamic measurement shall be for — (a) custody transfer ; (b) allocation: (c) fuel gas : or (d) flare gas. (4) Notwithstanding the provisions of subregulation (3) of this regulation, measurement methods in crude handling agreements, crude transportation agreements. gas sales or supply agreements, gas transportation agreements, and other commercial agreements for midstream and downstream petroleum Operations shall be as approved by the Authority. 7.—(1) The frequency of calibration of measurement systems shall be as prescribed in a guideline issued by the Authority. (2) A licensee or permit holder shall ensure that rneasurements and calibrations made under these Regulations have traceability to national or international measurement standards. (3) A licensee or permit holder shall ensure that an instrument used for calibration has traceability to national or international measurement standards. (4) A third-party measurement laboratory used to calibrate equipment covered by these Regulations shall — (a) be accredited in accordance with national and international recognised standards ; and (b) have a documented uncertainty equal to or better than those set out in these Regulations. (5) A licensee or permit holder shall ensure that a laboratory analysis of the composition or quality of natural gas or its derivatives, crude oil or its derivatives, condensate, petroleum liquids, petroleum products or any other form of petroleum liquids for custody transfer and allocation purposes is carried out by an accredited measurement laboratory and witnessed by the Authority. 8.—(1) The reference conditions for temperature and pressure to determine standard volume is 60 °F and 14.696 psia (101.325 kPa) for crude oil and condensate, (2) A reference pressure other than 101.325 kPa may be used for natural gas liquid and liquefied petroleum gas B25 Cla: of dynamie Measurement. Calibration and traceability. Reference conditions.
RegulationsPDF20232023-026